BSH Construction Panel, Aluminium


Standard scope of delivery (variants available on request).

Ceramic infrared radiators HSR or HTS, T-HTS, fitted
Radiators can be chosen from the radiator power levels 250 W, 400 W and 600 W. Mixed radiator wattages can also be fitted. One thermocouple radiator is provided for each construction panel equipped with HTS.

Extruded AL-frame sections with AL-square section and capping sections made from stainless steel, fitted
These components are used to surround the ceramic infrared radiators fixed to the MBO mounting sheets. The square section with a side upstand enables the BSH construction panels to be hung into a steel section frame to be built on site.

AK bipolar terminal clamps, fitted and connected with radiator power leads
For the electrical wiring of the individual radiators in connection with heat resistant insulated nickel wires and connection of the thermocouple radiator with the heat resistant insulated thermo line.

Mounting units, enclosed, individual parts are not fitted
A mounting unit contains an angle section, up to 3 heat resistant flexible metal hoses 1m long and PG 16 and other screw fitting accessories. The hoses are used to hold the nickel wire and thermo line and to protect them from mechanical stress. The mounting units can be fixed to anywhere on the BSH frame section.

Wiring material (nickel wire, thermo line), enclosed
Nickel wire (2.5 mm², max. 500 °C, max. 11 A) is supplied for the electrical wiring of the ceramic infrared radiators. The thermo line (1 mm², max. 400 °C) is used to connect the thermocouple to the controller. The Elstein product range includes a compensating line (1 mm², max. 100 °C) for extending this connection outside the IR radiation area.

Further information and safety information are given in the technical explanations of this brochure. The BSH mounting instruction also includes safety information as well as further details about the installation and the electrical connection.